Available in 1 /2/3/4 Change Over contacts Rated Contact Switching current up to 48A Coil Voltage available DC : 5/12/24/48/60/80/110/125/ 220 V AC: 6/12/24/42/48/60/80/110/115/120/127/220/ 230/240 Versions with coil overvoltage suppression Versions with Flag indicators & Manual relay Test Push Buttons with the possibility of latching the normally open contacts closed Mounting on PCB
CONCTACT USAvailable in 1 /2/3/4 Change Over contacts Rated Contact Switching current up to 48A Coil Voltage available DC : 5/12/24/48/60/80/110/125/ 220 V AC : 6/12/24/42/48/60/80/110/115/120/127/220/230/240 Versions with coil overvoltage suppression Versions with Flag indicators & Manual relay Test Push Buttons with the possibility of latching the normally open contacts closed Mounting on PCB
Bistable - impulse relays with/without memory, 1 CO, 2CO, control voltage: 230 VAC, 24 V AC/DC. Cooperation with illuminated momentary bell switches and control buttons.
Bistable - impulse relays, with/without memory, RESISTANCE TO INRUSH CURRENT 120 A (20 ms), 1 NO,2NO, control voltage: 230 VAC, 24 V AC/DC.
Electromagnetic relays are applied in solar systems for two main purposes 1. At the DC side, they switch on and off the DC voltage generated by photovoltaic cells. 2. At the AC side, they connect to / disconnect the entire system from the power network. Rated Contact Switching current 16 A ---48 A Contact clearance of minimum 1.5 mm. Resistance of the contact clearance to surge voltage of 2500 V. Low Power consumption of coil of 0.4 W Popular Types RS35/ RS50/ RUC/ RUC-M Mounting on PCB.
Sockets Push-in technology, Sockets for miniature relays, Sockets for R2M, Sockets for RY2, Sockets for RUC and RUC-M.
Sockets for interface relays, Sockets and accessories for relays SIR6W/B.
Product Details Electromagnetic relays are applied in solar systems for two main purposes 1. At the DC side, they switch on and off the DC voltage generated by photovoltaic cells. 2. At the AC side, they connect to / disconnect the entire system from the power network. Rated Contact Switching current 16 A ---48 A Contact clearance of minimum 1.5 mm. Resistance of the contact clearance to surge voltage of 2500 V. Low Power consumption of coil of 0.4 W Popular Types RS35/ RS50/ RUC/ RUC-M Mounting on PCB Approvals- ROHS; CE; VDE; DIN VDE 0126-1-1
Product Details Relays electromechanical components consists of a special set of contacts in accordance with EN 50205 (IEC 61810-3 in the future), in which all contacts are connected together so that NO and NC contacts are never closed simultaneously in the failed condition. In opposition to standard relays, this allows for monitoring the switch position of the relay, even if one of the contacts does not open. The main application areas of our relays are currently Industrial Automation Robotics Mechanical Engineering Laser and Welding Technology Medical Technology Elevators / Lifting Systems Process Technology Railway Engineering Combustion Plants Building Control.